The Fisher FIELDVUE DVC6200 is a high-performance digital valve controller that converts a 4-20 mA control signal into pneumatic output for accurate valve positioning. It supports HART communication for setup, monitoring, and diagnostics, helping operations stay closer to setpoint for better process control and product quality. Available in aluminum or stainless steel, it works with single- or double-acting actuators in linear or rotary applications.
| Communication Protocol | 4-20 mA HART (HART 5 or HART 7 selectable) |
| Input Signal | 4-20 mA DC, nominal; minimum voltage 9.5 V DC for analog control, 10 V DC for HART |
| Supply Pressure | Minimum recommended 0.3 bar / 5 psig above actuator requirements; maximum 10.0 bar / 145 psig |
| Output Signal | Pneumatic up to full supply pressure; minimum span 0.4 bar / 6 psig, maximum span 9.5 bar / 140 psig |
| Steady-State Air Consumption (standard relay) | <0.38 Nm³/h / 14 scfh at 1.4 bar / 20 psig; <1.3 Nm³/h / 49 scfh at 5.5 bar / 80 psig |
| Low Bleed Relay | Average 0.056 Nm³/h / 2.1 scfh at 1.4 bar; 0.184 Nm³/h / 6.9 scfh at 5.5 bar |
| Maximum Output Capacity | 10.0 Nm³/h / 375 scfh at 1.4 bar; 29.5 Nm³/h / 1100 scfh at 5.5 bar |
| Operating Temperature | -40 to +85 °C / -40 to +185 °F (standard); -52 to +85 °C / -62 to +185 °F with fluorosilicone elastomers |
| Enclosure Protection | IP66/Type 4X |
| Housing Materials | Low-copper aluminum (standard) or stainless steel (optional) |
| Mounting | Integral to Fisher 657/667/GX actuators; compliant with IEC 60534-6-1/-6-2, VDI/VDE 3845, NAMUR; remote-mount options available |
| Certifications | Explosion Proof, Intrinsically Safe, Non-incendive, Flame Proof (CSA, FM, ATEX, IECEx) |
Widely used for control valve positioning in oil & gas, refining, chemical processing, power generation, and pulp & paper industries—especially where diagnostics help reduce unplanned downtime and improve loop performance.
Email: tracychen@gbsxj.com
WhatsApp: +8617799852698
Phone/wechat: 13032169170
Consider the DVC6200 SIS for safety instrumented systems, or the DVC6200f/P for FOUNDATION fieldbus/PROFIBUS PA protocols.